ML-1366 Input / Output Modules

Features

Offering superior operating performance with VIP communication protocol, I/O modules can be programmed to work in cause and effect scenarios and fire automation can be performed.

– Complies with EN 54-17 and EN 54-18 standards
– Model option with short circuit isolator
– LED indicators for system activation, activation, error conditions and communication status
– Easy installation with rail system
– 2 zone monitoring inputs, 1 siren output option or 2 dry contact monitoring inputs and 1 dry contact relay output option with 2/1 I/O module
– 4/2 I/O module with 4 dry contact monitoring inputs and 2 dry contact relay output options

Dry Contact Input / Output Modules

The modules get their energy from the cycle and can be programmed to work in a cause and effect scenario. Within the fire automation, desired environmental systems can be monitored with contact monitoring inputs and desired environmental systems can be controlled with relay outputs.
Contact monitoring inputs are used to monitor the external dry contact (voltage-free) relay output. The contact has normally open and normally closed operation. The type of event that the switchboard will detect in case of a change in the contact status can be determined by the user.
The double-pole dry contact (voltage-free) relay output, which can withstand a maximum current of 30V DC, 1A, has normally open and normally closed contact positions. It can be set to give output according to the event type determined by the user.
In models with SCI feature, it isolates the line in case of a short circuit error thanks to the internal short circuit isolator.

Powered Input / Output Modules

It requires an external power supply of 18V – 30V DC and this source can be monitored for error conditions. It can be programmed to operate in a cause and effect scenario.
Contact monitoring inputs are used to monitor the external dry contact (voltage-free) relay output. The contact has normally open and normally closed operation. The type of event that the switchboard will detect in case of a change in the contact status can be determined by the user.
The 24V DC 500mA siren output can be activated as desired within the fire automation. It can be set to give an output according to the event type determined by the user.
In models with SCI feature, it isolates the line in case of a short circuit error thanks to the internal short circuit isolator.

Be the first to comment on this product!
You can use the suggestion form to submit feedback on the product's price, image, description, or any other insufficient areas.
Thank you for your feedback and suggestions.
ML-1366 Input / Output Modules Z6K77G95LF ML-1366 Input / Output Modules